ICD-10-PCS 2027 procedure code
0JH63AZInsertion of Contractility Modulation Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
Short description: Insert Contractil Mod Dev in Chest Subcu/Fascia, Perc
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JH63AZ
0JH63AZ is the ICD-10-PCS code for a insertion procedure on the subcutaneous tissue and fascia, chest using a percutaneous approach with contractility modulation device. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
In plain terms, this corresponds to implantation or replacement of cardiac contractility modulation [CCM] rechargeable pulse generator only, the ICD-9-CM procedure title it maps to (17.52).
For a different body part, codes include 0JH83AZ (subcutaneous tissue and fascia, abdomen).
The same procedure with a different approach is coded 0JH60AZ (open).
With a different device, use 0JH630Z (monitoring device, hemodynamic), 0JH632Z (monitoring device), 0JH634Z (pacemaker, single chamber), 0JH635Z (pacemaker, single chamber rate responsive), 0JH636Z (pacemaker, dual chamber), 0JH637Z (cardiac resynchronization pacemaker pulse generator) and 15 more.
It is an operating-room procedure in the MS-DRG logic for DRG 245 (AICD Generator Procedures), under the surgical category “AICD Generator Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- 6Subcutaneous Tissue and Fascia, Chest
Includes: Pectoral fascia
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- AContractility Modulation Device
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
- 0JH630ZMonitoring Device, Hemodynamic
- 0JH632ZMonitoring Device
- 0JH634ZPacemaker, Single Chamber
- 0JH635ZPacemaker, Single Chamber Rate Responsive
- 0JH636ZPacemaker, Dual Chamber
- 0JH637ZCardiac Resynchronization Pacemaker Pulse Generator
- 0JH638ZDefibrillator Generator
- 0JH639ZCardiac Resynchronization Defibrillator Pulse Generator
- 0JH63BZStimulator Generator, Single Array
- 0JH63CZStimulator Generator, Single Array Rechargeable
- 0JH63DZStimulator Generator, Multiple Array
- 0JH63EZStimulator Generator, Multiple Array Rechargeable
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · AICD Generator Procedures
ICD-9-CM equivalent
Converter →- 17.52Implantation or replacement of cardiac contractility modulation [CCM] rechargeable pulse generator onlyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0JH63AZ
Is 0JH63AZ a valid ICD-10-PCS code for 2027?
- Yes. 0JH63AZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0JH63AZ an O.R. procedure?
- Yes. 0JH63AZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0JH63AZ group to?
- Depending on the principal diagnosis, 0JH63AZ can group to MS-DRG 245.
What is the ICD-9 procedure code for 0JH63AZ?
- The CMS GEMs map 0JH63AZ to ICD-9-CM 17.52 (Implantation or replacement of cardiac contractility modulation [CCM] rechargeable pulse generator only).