ICD-10-PCS 2027 procedure code
0JH632ZInsertion of Monitoring Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
Short description: Insert of Monitor Dev into Chest Subcu/Fascia, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JH632Z
0JH632Z is the ICD-10-PCS code for a insertion procedure on the subcutaneous tissue and fascia, chest using a percutaneous approach with monitoring device. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.
In plain terms, this corresponds to revision or relocation of cardiac device pocket and other incision of skin and subcutaneous tissue, the ICD-9-CM procedure titles it maps to (37.79 and 86.09).
For a different body part, codes include 0JH832Z (subcutaneous tissue and fascia, abdomen).
The same procedure with a different approach is coded 0JH602Z (open).
With a different device, use 0JH630Z (monitoring device, hemodynamic), 0JH634Z (pacemaker, single chamber), 0JH635Z (pacemaker, single chamber rate responsive), 0JH636Z (pacemaker, dual chamber), 0JH637Z (cardiac resynchronization pacemaker pulse generator), 0JH638Z (defibrillator generator) and 15 more.
It is an operating-room procedure in the MS-DRG logic for DRG 040 (Peripheral, Cranial Nerve and Other Nervous System Procedures with MCC), DRG 041 (Peripheral, Cranial Nerve and Other Nervous System Procedures with CC or Peripheral Neurostimulator), DRG 042 (Peripheral, Cranial Nerve and Other Nervous System Procedures without CC/MCC), DRG 210 (Cardiac Pacemaker Revision or Device Replacement with MCC), DRG 211 (Cardiac Pacemaker Revision or Device Replacement without MCC) and DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), under the surgical categories “Peripheral, Cranial Nerve and Other Nervous System Procedures”, “Cardiac Pacemaker Revision or Device Replacement”, “Other Skin, Subcutaneous Tissue and Breast Procedures” and 2 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- HInsertion
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part
Includes: Insertion of radioactive implant, insertion of central venous catheter
- 4. Body Part
- 6Subcutaneous Tissue and Fascia, Chest
Includes: Pectoral fascia
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 2Monitoring Device
Includes: Blood glucose monitoring system; Cardiac event recorder; Continuous Glucose Monitoring (CGM) device; Implantable glucose monitoring device; Loop recorder, implantable; Reveal (LINQ)(DX)(XT)
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
- 0JH630ZMonitoring Device, Hemodynamic
- 0JH634ZPacemaker, Single Chamber
- 0JH635ZPacemaker, Single Chamber Rate Responsive
- 0JH636ZPacemaker, Dual Chamber
- 0JH637ZCardiac Resynchronization Pacemaker Pulse Generator
- 0JH638ZDefibrillator Generator
- 0JH639ZCardiac Resynchronization Defibrillator Pulse Generator
- 0JH63AZContractility Modulation Device
- 0JH63BZStimulator Generator, Single Array
- 0JH63CZStimulator Generator, Single Array Rechargeable
- 0JH63DZStimulator Generator, Multiple Array
- 0JH63EZStimulator Generator, Multiple Array Rechargeable
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Peripheral, Cranial Nerve and Other Nervous System Procedures
MDC 05 · Diseases and Disorders of the Circulatory System · Cardiac Pacemaker Revision or Device Replacement
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 37.79Revision or relocation of cardiac device pocketapproximate
- 86.09Other incision of skin and subcutaneous tissueapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0JH632Z
Is 0JH632Z a valid ICD-10-PCS code for 2027?
- Yes. 0JH632Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0JH632Z an O.R. procedure?
- Yes. 0JH632Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0JH632Z group to?
- Depending on the principal diagnosis, 0JH632Z can group to MS-DRG 040, MS-DRG 041, MS-DRG 042, MS-DRG 210, MS-DRG 211 and MS-DRG 579.
What is the ICD-9 procedure code for 0JH632Z?
- The CMS GEMs map 0JH632Z to ICD-9-CM 37.79 (Revision or relocation of cardiac device pocket) and 86.09 (Other incision of skin and subcutaneous tissue).