Skip to content
Dx

ICD-10-PCS 2027 procedure code

F01F5YZRange of Motion and Joint Integrity Assessment of Integumentary System - Upper Back / Upper Extremity using Other Equipment

✓ Valid for 2027Non-O.R. procedure

Short description: ROM/Jt Integrity Assess Integu Up Back/UE w Oth Equip

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About F01F5YZ

F01F5YZ is the ICD-10-PCS code for a motor and/or nerve function assessment procedure on the integumentary system - upper back / upper extremity using a range of motion and joint integrity approach with other equipment (qualifier: none). In ICD-10-PCS, motor and/or nerve function assessment means measurement of motor, nerve, and related functions.

In plain terms, this corresponds to range of motion testing, the ICD-9-CM procedure title it maps to (93.05).

For a different body part, codes include F0105YZ (neurological system - head and neck), F0115YZ (neurological system - upper back / upper extremity), F0125YZ (neurological system - lower back / lower extremity), F0135YZ (neurological system - whole body), F01D5YZ (integumentary system - head and neck), F01G5YZ (integumentary system - lower back / lower extremity) and 5 more.

The same procedure with a different approach is coded F01F0YZ (muscle performance) and F01F6YZ (sensory awareness/processing/integrity).

With a different device, use F01F5ZZ (none).

It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 945 (Rehabilitation with CC/MCC) and DRG 946 (Rehabilitation without CC/MCC), under the surgical category “Rehabilitation”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
FPhysical Rehabilitation and Diagnostic Audiology
2. Section Qualifier
0Rehabilitation
3. Type
1Motor and/or Nerve Function Assessment

Measurement of motor, nerve, and related functions

4. Body System / Region
FIntegumentary System - Upper Back / Upper Extremity
5. Type Qualifier
5Range of Motion and Joint Integrity

Measures quantity, quality, grade, and classification of joint movement and/or mobility

Range of Motion is the space, distance or angle through which movement occurs at a joint or series of joints. Joint integrity is the conformance of joints to expected anatomic, biomechanical and kinematic norms

6. Equipment
YOther Equipment
7. Qualifier
ZNone

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 23 · Factors Influencing Health Status and Other Contacts with Health Services · Rehabilitation

ICD-9-CM equivalent

Converter →
  • 93.05Range of motion testingapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about F01F5YZ

Is F01F5YZ a valid ICD-10-PCS code for 2027?

Yes. F01F5YZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is F01F5YZ an O.R. procedure?

No. F01F5YZ is designated non-O.R. in MS-DRG v44.0.

What DRG does F01F5YZ group to?

Depending on the principal diagnosis, F01F5YZ can group to MS-DRG 945 and MS-DRG 946.

What is the ICD-9 procedure code for F01F5YZ?

The CMS GEMs map F01F5YZ to ICD-9-CM 93.05 (Range of motion testing).