Skip to content
Dx

ICD-10-PCS 2027 procedure code

0YUA4JZSupplement Bilateral Inguinal Region with Synthetic Substitute, Percutaneous Endoscopic Approach

✓ Valid for 2027O.R. procedure

Short description: Supplement Bi Inguinal Region w Synth Sub, Perc Endo

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0YUA4JZ

0YUA4JZ is the ICD-10-PCS code for a supplement procedure on the bilateral inguinal region using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to laparoscopic bilateral repair of inguinal hernia with graft or prosthesis, not otherwise specified, the ICD-9-CM procedure title it maps to (17.24).

For a different body part, codes include 0YU04JZ (right buttock), 0YU14JZ (left buttock), 0YU54JZ (right inguinal region), 0YU64JZ (left inguinal region), 0YU74JZ (right femoral region), 0YU84JZ (left femoral region) and 23 more.

The same procedure with a different approach is coded 0YUA0JZ (open).

With a different device, use 0YUA47Z (autologous tissue substitute) and 0YUA4KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 350 (Inguinal and Femoral Hernia Procedures with MCC), DRG 351 (Inguinal and Femoral Hernia Procedures with CC) and DRG 352 (Inguinal and Femoral Hernia Procedures without CC/MCC), under the surgical category “Hernia Procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
YAnatomical Regions, Lower Extremities
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
AInguinal Region, Bilateral

Includes: Inguinal canal; Inguinal triangle

5. Approach
4Percutaneous Endoscopic

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 17.24Laparoscopic bilateral repair of inguinal hernia with graft or prosthesis, not otherwise specifiedapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0YUA4JZ

Is 0YUA4JZ a valid ICD-10-PCS code for 2027?

Yes. 0YUA4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0YUA4JZ an O.R. procedure?

Yes. 0YUA4JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0YUA4JZ group to?

Depending on the principal diagnosis, 0YUA4JZ can group to MS-DRG 350, MS-DRG 351 and MS-DRG 352.

What is the ICD-9 procedure code for 0YUA4JZ?

The CMS GEMs map 0YUA4JZ to ICD-9-CM 17.24 (Laparoscopic bilateral repair of inguinal hernia with graft or prosthesis, not otherwise specified).