Skip to content
Dx

ICD-10-PCS 2027 procedure code

0UW88JZRevision of Synthetic Substitute in Fallopian Tube, Via Natural or Artificial Opening Endoscopic

✓ Valid for 2027O.R. procedureFemale only

Short description: Revision of Synthetic Substitute in Fallopian Tube, Endo

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0UW88JZ

0UW88JZ is the ICD-10-PCS code for a revision procedure on the fallopian tube using a via natural or artificial opening endoscopic approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Salpingotomy, the ICD-9-CM procedure title it maps to (66.01).

For a different body part, codes include 0UWD8JZ (uterus and cervix) and 0UWH8JZ (vagina and cul-de-sac).

The same procedure with a different approach is coded 0UW80JZ (open), 0UW83JZ (percutaneous), 0UW84JZ (percutaneous endoscopic), 0UW87JZ (via natural or artificial opening) and 0UW8XJZ (external).

With a different device, use 0UW880Z (drainage device), 0UW883Z (infusion device), 0UW887Z (autologous tissue substitute), 0UW88CZ (extraluminal device), 0UW88DZ (intraluminal device), 0UW88KZ (nonautologous tissue substitute) and 1 more.

It is an operating-room procedure in the MS-DRG logic for DRG 731 (Uterine and Adnexa Procedures for Malignancy with MCC), DRG 732 (Uterine and Adnexa Procedures for Malignancy with CC), DRG 733 (Uterine and Adnexa Procedures for Malignancy without CC/MCC), DRG 742 (Uterine and Adnexa Procedures for Non-Malignancy with CC/MCC) and DRG 743 (Uterine and Adnexa Procedures for Non-Malignancy without CC/MCC), under the surgical categories “Uterine and Adnexa Procedures for Malignancy” and “Uterine and Adnexa Procedures for Non-Malignancy”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
UFemale Reproductive System
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
8Fallopian Tube
5. Approach
8Via Natural or Artificial Opening Endoscopic

Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 13 · Diseases and Disorders of the Female Reproductive System · Uterine and Adnexa Procedures for Non-Malignancy

ICD-9-CM equivalent

Converter →
  • 66.01Salpingotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0UW88JZ

Is 0UW88JZ a valid ICD-10-PCS code for 2027?

Yes. 0UW88JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0UW88JZ an O.R. procedure?

Yes. 0UW88JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0UW88JZ group to?

Depending on the principal diagnosis, 0UW88JZ can group to MS-DRG 731, MS-DRG 732, MS-DRG 733, MS-DRG 742 and MS-DRG 743.

What is the ICD-9 procedure code for 0UW88JZ?

The CMS GEMs map 0UW88JZ to ICD-9-CM 66.01 (Salpingotomy).