Skip to content
Dx

ICD-10-PCS 2027 procedure code

0TW98DZRevision of Intraluminal Device in Ureter, Via Natural or Artificial Opening Endoscopic

✓ Valid for 2027O.R. procedure

Short description: Revision of Intraluminal Device in Ureter, Endo

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0TW98DZ

0TW98DZ is the ICD-10-PCS code for a revision procedure on the ureter using a via natural or artificial opening endoscopic approach with intraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Ureterotomy, the ICD-9-CM procedure title it maps to (56.2).

For a different body part, codes include 0TW58DZ (kidney), 0TWB8DZ (bladder) and 0TWD8DZ (urethra).

The same procedure with a different approach is coded 0TW90DZ (open), 0TW93DZ (percutaneous), 0TW94DZ (percutaneous endoscopic), 0TW97DZ (via natural or artificial opening) and 0TW9XDZ (external).

With a different device, use 0TW980Z (drainage device), 0TW982Z (monitoring device), 0TW983Z (infusion device), 0TW987Z (autologous tissue substitute), 0TW98CZ (extraluminal device), 0TW98JZ (synthetic substitute) and 3 more.

It is an operating-room procedure in the MS-DRG logic for DRG 656 (Kidney and Ureter Procedures for Neoplasm with MCC), DRG 657 (Kidney and Ureter Procedures for Neoplasm with CC), DRG 658 (Kidney and Ureter Procedures for Neoplasm without CC/MCC), DRG 659 (Kidney and Ureter Procedures for Non-Neoplasm with MCC), DRG 660 (Kidney and Ureter Procedures for Non-Neoplasm with CC) and DRG 661 (Kidney and Ureter Procedures for Non-Neoplasm without CC/MCC), under the surgical categories “” and “Kidney and Ureter Procedures for Non-Neoplasm”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
TUrinary System
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
9Ureter

Includes: Ureteral orifice; Ureterovesical orifice

5. Approach
8Via Natural or Artificial Opening Endoscopic

Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure

6. Device
DIntraluminal Device

Includes: Absolute Pro Vascular (OTW) Self-Expanding Stent System; Acculink (RX) Carotid Stent System; AFX(R) Endovascular AAA System; AneuRx(R) AAA Advantage(R); Assurant (Cobalt) stent; Carotid WALLSTENT(R) Monorail(R) Endoprosthesis; CoAxia NeuroFlo catheter; Colonic Z-Stent(R); Complete (SE) stent; Cook Zenith AAA Endovascular Graft; Driver stent (RX) (OTW); E-Luminexx(tm) (Biliary)(Vascular) Stent; Embolization coil(s); Endologix AFX(R) Endovascular AAA System; Endurant(R) Endovascular Stent Graft; Endurant(R) II AAA stent graft system; EXCLUDER(R) AAA Endoprosthesis; Express(R) (LD) Premounted Stent System; Express(R) Biliary SD Monorail(R) Premounted Stent System; Express(R) SD Renal Monorail(R) Premounted Stent System; FLAIR(R) Endovascular Stent Graft; Formula(tm) Balloon-Expandable Renal Stent System; GORE EXCLUDER(R) AAA Endoprosthesis; GORE TAG(R) Thoracic Endoprosthesis; GORE(R) VIABAHN(R) Endoprosthesis; GORE(R) VIABIL(R) Biliary Endoprosthesis; Herculink (RX) Elite Renal Stent System; Innova(tm) stent; LifeStent(R) (Flexstar)(XL) Vascular Stent System; Medtronic Endurant(R) II AAA stent graft system; Micro-Driver stent (RX) (OTW); MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System; Omnilink Elite Vascular Balloon Expandable Stent System; Protege(R) RX Carotid Stent System; Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary); Talent(R) Converter; Talent(R) Occluder; Talent(R) Stent Graft (abdominal)(thoracic); Therapeutic occlusion coil(s); Ultraflex(tm) Precision Colonic Stent System; Valiant Thoracic Stent Graft; WALLSTENT(R) Endoprosthesis; Xact Carotid Stent System; Zenith AAA Endovascular Graft; Zenith Flex(R) AAA Endovascular Graft; Zenith TX2(R) TAA Endovascular Graft; Zenith(R) Renu(tm) AAA Ancillary Graft

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 56.2Ureterotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0TW98DZ

Is 0TW98DZ a valid ICD-10-PCS code for 2027?

Yes. 0TW98DZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0TW98DZ an O.R. procedure?

Yes. 0TW98DZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0TW98DZ group to?

Depending on the principal diagnosis, 0TW98DZ can group to MS-DRG 656, MS-DRG 657, MS-DRG 658, MS-DRG 659, MS-DRG 660 and MS-DRG 661.

What is the ICD-9 procedure code for 0TW98DZ?

The CMS GEMs map 0TW98DZ to ICD-9-CM 56.2 (Ureterotomy).