ICD-10-PCS 2027 procedure code
0MRT4JZReplacement of Left Foot Bursa and Ligament with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Replace L Foot Bursa/Lig w Synth Sub, Perc Endo
Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0MRT4JZ
0MRT4JZ is the ICD-10-PCS code for a replacement procedure on the left foot bursa and ligament using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to other repair of joint, the ICD-9-CM procedure title it maps to (81.96).
For a different body part, codes include 0MR04JZ (head and neck bursa and ligament), 0MR14JZ (right shoulder bursa and ligament), 0MR24JZ (left shoulder bursa and ligament), 0MR34JZ (right elbow bursa and ligament), 0MR44JZ (left elbow bursa and ligament), 0MR54JZ (right wrist bursa and ligament) and 21 more.
The same procedure with a different approach is coded 0MRT0JZ (open).
With a different device, use 0MRT47Z (autologous tissue substitute) and 0MRT4KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 503 (Foot Procedures with MCC), DRG 504 (Foot Procedures with CC), DRG 505 (Foot Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Foot Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.
It was added in FY2018, effective October 1, 2017.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- MBursae and Ligaments
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- TFoot Bursa and Ligament, Left
Includes: Calcaneocuboid ligament; Cuneonavicular ligament; Intercuneiform ligament; Interphalangeal ligament; Metatarsal ligament; Metatarsophalangeal ligament; Subtalar ligament; Talocalcaneal ligament; Talocalcaneonavicular ligament; Tarsometatarsal ligament
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 0MR04JZHead and Neck Bursa and Ligament
- 0MR14JZShoulder Bursa and Ligament, Right
- 0MR24JZShoulder Bursa and Ligament, Left
- 0MR34JZElbow Bursa and Ligament, Right
- 0MR44JZElbow Bursa and Ligament, Left
- 0MR54JZWrist Bursa and Ligament, Right
- 0MR64JZWrist Bursa and Ligament, Left
- 0MR74JZHand Bursa and Ligament, Right
- 0MR84JZHand Bursa and Ligament, Left
- 0MR94JZUpper Extremity Bursa and Ligament, Right
- 0MRB4JZUpper Extremity Bursa and Ligament, Left
- 0MRC4JZUpper Spine Bursa and Ligament
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Foot Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 81.96Other repair of jointapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2018 (effective 10/1/2017): Added
- No changes since FY2018.
Common questions about 0MRT4JZ
Is 0MRT4JZ a valid ICD-10-PCS code for 2027?
- Yes. 0MRT4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0MRT4JZ an O.R. procedure?
- Yes. 0MRT4JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0MRT4JZ group to?
- Depending on the principal diagnosis, 0MRT4JZ can group to MS-DRG 503, MS-DRG 504, MS-DRG 505, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0MRT4JZ?
- The CMS GEMs map 0MRT4JZ to ICD-9-CM 81.96 (Other repair of joint).