ICD-10-PCS 2027 procedure code
0JWV3XZRevision of Tunneled Vascular Access Device in Upper Extremity Subcutaneous Tissue and Fascia, Percutaneous Approach
Short description: Revise Tunnel VAD in Up Extrem Subcu/Fascia, Perc
Code last changed in FY2018 (effective October 1, 2017). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JWV3XZ
0JWV3XZ is the ICD-10-PCS code for a revision procedure on the subcutaneous tissue and fascia, upper extremity using a percutaneous approach with vascular access device, tunneled. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of skin and subcutaneous tissue, the ICD-9-CM procedure title it maps to (86.09).
For a different body part, codes include 0JWT3XZ (subcutaneous tissue and fascia, trunk) and 0JWW3XZ (subcutaneous tissue and fascia, lower extremity).
The same procedure with a different approach is coded 0JWV0XZ (open) and 0JWVXXZ (external).
With a different device, use 0JWV30Z (drainage device), 0JWV33Z (infusion device), 0JWV37Z (autologous tissue substitute), 0JWV3HZ (contraceptive device), 0JWV3JZ (synthetic substitute), 0JWV3KZ (nonautologous tissue substitute) and 4 more.
It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), DRG 580 (Other Skin, Subcutaneous Tissue and Breast Procedures with CC) and DRG 581 (Other Skin, Subcutaneous Tissue and Breast Procedures without CC/MCC), under the surgical category “Other Skin, Subcutaneous Tissue and Breast Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- VSubcutaneous Tissue and Fascia, Upper Extremity
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- XVascular Access Device, Tunneled
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
ICD-9-CM equivalent
Converter →- 86.09Other incision of skin and subcutaneous tissueapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- FY2018 (effective 10/1/2017): Title revised — was “Revision of Vascular Access Device in Upper Extremity Subcutaneous Tissue and Fascia, Percutaneous Approach”
Common questions about 0JWV3XZ
Is 0JWV3XZ a valid ICD-10-PCS code for 2027?
- Yes. 0JWV3XZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0JWV3XZ an O.R. procedure?
- No. 0JWV3XZ is designated non-O.R. in MS-DRG v44.0.
What DRG does 0JWV3XZ group to?
- Depending on the principal diagnosis, 0JWV3XZ can group to MS-DRG 579, MS-DRG 580 and MS-DRG 581.
What is the ICD-9 procedure code for 0JWV3XZ?
- The CMS GEMs map 0JWV3XZ to ICD-9-CM 86.09 (Other incision of skin and subcutaneous tissue).