ICD-10-PCS 2027 procedure code
0JWTXFZRevision of Subcutaneous Defibrillator Lead in Trunk Subcutaneous Tissue and Fascia, External Approach
Short description: Revise Subcu Defib Lead in Trunk Subcu/Fascia, Extern
Code last changed in FY2020 (effective October 1, 2019). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0JWTXFZ
0JWTXFZ is the ICD-10-PCS code for a revision procedure on the subcutaneous tissue and fascia, trunk using an external approach with subcutaneous defibrillator lead. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
The same procedure with a different approach is coded 0JWT0FZ (open) and 0JWT3FZ (percutaneous).
With a different device, use 0JWTX0Z (drainage device), 0JWTX2Z (monitoring device), 0JWTX3Z (infusion device), 0JWTX7Z (autologous tissue substitute), 0JWTXHZ (contraceptive device), 0JWTXJZ (synthetic substitute) and 7 more.
It doesn't appear in the MS-DRG procedure index, so on its own it doesn't change the DRG assignment.
It was added in FY2020, effective October 1, 2019.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- JSubcutaneous Tissue and Fascia
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- TSubcutaneous Tissue and Fascia, Trunk
Includes: External oblique aponeurosis; Transversalis fascia
- 5. Approach
- XExternal
Procedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane
- 6. Device
- FSubcutaneous Defibrillator Lead
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
Different device
- 0JWTX0ZDrainage Device
- 0JWTX2ZMonitoring Device
- 0JWTX3ZInfusion Device
- 0JWTX7ZAutologous Tissue Substitute
- 0JWTXHZContraceptive Device
- 0JWTXJZSynthetic Substitute
- 0JWTXKZNonautologous Tissue Substitute
- 0JWTXMZStimulator Generator
- 0JWTXNZTissue Expander
- 0JWTXPZCardiac Rhythm Related Device
- 0JWTXVZInfusion Device, Pump
- 0JWTXWZVascular Access Device, Totally Implantable
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2020 (effective 10/1/2019): Added
- No changes since FY2020.
Common questions about 0JWTXFZ
Is 0JWTXFZ a valid ICD-10-PCS code for 2027?
- Yes. 0JWTXFZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.