ICD-10-PCS 2027 procedure code
07WK4CZRevision of Extraluminal Device in Thoracic Duct, Percutaneous Endoscopic Approach
Short description: Revise of Extralum Dev in Thoracic Duct, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 07WK4CZ
07WK4CZ is the ICD-10-PCS code for a revision procedure on the thoracic duct using a percutaneous endoscopic approach with extraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other operations on thoracic duct, the ICD-9-CM procedure title it maps to (40.69).
For a different body part, codes include 07WL4CZ (cisterna chyli) and 07WN4CZ (lymphatic).
The same procedure with a different approach is coded 07WK0CZ (open), 07WK3CZ (percutaneous) and 07WKXCZ (external).
With a different device, use 07WK40Z (drainage device), 07WK43Z (infusion device), 07WK47Z (autologous tissue substitute), 07WK4DZ (intraluminal device), 07WK4JZ (synthetic substitute), 07WK4KZ (nonautologous tissue substitute) and 1 more.
It is an operating-room procedure in the MS-DRG logic for DRG 163 (Major Chest Procedures with MCC), DRG 164 (Major Chest Procedures with CC) and DRG 165 (Major Chest Procedures without CC/MCC), under the surgical category “Major Chest Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 7Lymphatic and Hemic Systems
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- KThoracic Duct
Includes: Left jugular trunk; Left subclavian trunk
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- CExtraluminal Device
Includes: AtriClip LAA Exclusion System; LAP-BAND(R) adjustable gastric banding system; REALIZE(R) Adjustable Gastric Band
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 04 · Diseases and Disorders of the Respiratory System · Major Chest Procedures
ICD-9-CM equivalent
Converter →- 40.69Other operations on thoracic ductapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 07WK4CZ
Is 07WK4CZ a valid ICD-10-PCS code for 2027?
- Yes. 07WK4CZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 07WK4CZ an O.R. procedure?
- Yes. 07WK4CZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 07WK4CZ group to?
- Depending on the principal diagnosis, 07WK4CZ can group to MS-DRG 163, MS-DRG 164 and MS-DRG 165.
What is the ICD-9 procedure code for 07WK4CZ?
- The CMS GEMs map 07WK4CZ to ICD-9-CM 40.69 (Other operations on thoracic duct).