ICD-10-PCS 2027 procedure code
05W04MZRevision of Neurostimulator Lead in Azygos Vein, Percutaneous Endoscopic Approach
Short description: Revision of Neuro Lead in Azygos Vein, Perc Endo Approach
Code last changed in FY2017 (effective October 1, 2016). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 05W04MZ
05W04MZ is the ICD-10-PCS code for a revision procedure on the azygos vein using a percutaneous endoscopic approach with neurostimulator lead. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to implantation or replacement of peripheral neurostimulator lead(s), the ICD-9-CM procedure title it maps to (04.92).
For a different body part, codes include 05W34MZ (right innominate vein) and 05W44MZ (left innominate vein).
The same procedure with a different approach is coded 05W00MZ (open), 05W03MZ (percutaneous) and 05W0XMZ (external).
With a different device, use 05W042Z (monitoring device).
It is an operating-room procedure in the MS-DRG logic for DRG 040 (Peripheral, Cranial Nerve and Other Nervous System Procedures with MCC), DRG 041 (Peripheral, Cranial Nerve and Other Nervous System Procedures with CC or Peripheral Neurostimulator) and DRG 042 (Peripheral, Cranial Nerve and Other Nervous System Procedures without CC/MCC), under the surgical category “Peripheral, Cranial Nerve and Other Nervous System Procedures”.
It was added in FY2017, effective October 1, 2016.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 5Upper Veins
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 0Azygos Vein
Includes: Right ascending lumbar vein; Right subcostal vein
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- MNeurostimulator Lead
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
Different device
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Peripheral, Cranial Nerve and Other Nervous System Procedures
ICD-9-CM equivalent
Converter →- 04.92Implantation or replacement of peripheral neurostimulator lead(s)approximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2017 (effective 10/1/2016): Added
- No changes since FY2017.
Common questions about 05W04MZ
Is 05W04MZ a valid ICD-10-PCS code for 2027?
- Yes. 05W04MZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 05W04MZ an O.R. procedure?
- Yes. 05W04MZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 05W04MZ group to?
- Depending on the principal diagnosis, 05W04MZ can group to MS-DRG 040, MS-DRG 041 and MS-DRG 042.
What is the ICD-9 procedure code for 05W04MZ?
- The CMS GEMs map 05W04MZ to ICD-9-CM 04.92 (Implantation or replacement of peripheral neurostimulator lead(s)).