ICD-10-PCS 2027 procedure code
03PY3JZRemoval of Synthetic Substitute from Upper Artery, Percutaneous Approach
Short description: Removal of Synthetic Substitute from Up Art, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 03PY3JZ
03PY3JZ is the ICD-10-PCS code for a removal procedure on the upper artery using a percutaneous approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to removal of arteriovenous shunt for renal dialysis, the ICD-9-CM procedure title it maps to (39.43).
The same procedure with a different approach is coded 03PY0JZ (open) and 03PY4JZ (percutaneous endoscopic).
With a different device, use 03PY30Z (drainage device), 03PY32Z (monitoring device), 03PY33Z (infusion device), 03PY37Z (autologous tissue substitute), 03PY3CZ (extraluminal device), 03PY3DZ (intraluminal device) and 3 more.
It is an operating-room procedure in the MS-DRG logic for DRG 361 (Other Circulatory System O.R. Procedures with MCC), DRG 362 (Other Circulatory System O.R. Procedures without MCC), DRG 673 (Other Kidney and Urinary Tract Procedures with MCC), DRG 674 (Other Kidney and Urinary Tract Procedures with CC), DRG 675 (Other Kidney and Urinary Tract Procedures without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Other Circulatory System O.R. Procedures”, “Other Kidney and Urinary Tract Procedures”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 3Upper Arteries
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- YUpper Artery
Includes: Aortic intercostal artery; Bronchial artery; Esophageal artery; Subcostal artery
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Circulatory System O.R. Procedures
MDC 11 · Diseases and Disorders of the Kidney and Urinary Tract · Other Kidney and Urinary Tract Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 39.43Removal of arteriovenous shunt for renal dialysisapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 03PY3JZ
Is 03PY3JZ a valid ICD-10-PCS code for 2027?
- Yes. 03PY3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 03PY3JZ an O.R. procedure?
- Yes. 03PY3JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 03PY3JZ group to?
- Depending on the principal diagnosis, 03PY3JZ can group to MS-DRG 361, MS-DRG 362, MS-DRG 673, MS-DRG 674, MS-DRG 675 and MS-DRG 907.
What is the ICD-9 procedure code for 03PY3JZ?
- The CMS GEMs map 03PY3JZ to ICD-9-CM 39.43 (Removal of arteriovenous shunt for renal dialysis).